XCEM : SUBMERGED IMPLANTS

XCEM : SUBMERGED IMPLANTS

Submerged Fixture

 

 

a revolution in dental implants

 

SYLBUTMENT

The amazing SYLBUTMENT – the very first in the world!
The even surface contact of the circular grooved pattern
evenly distributes chewing force, which prevents
the screw from loosening and the abutment from swaying.

▶When the abutment screw is fastened,
elastic deformation occurs around the grooves of the
SYLBUTMENT, creating a force which moves the abutment and
fixture together.
Even when the force is removed, the sealing effect can still be
maintained

  • site map
  • Korean
SYLBUTMENT

The amazing SYLBUTMENT – the very first in the world!
The even surface contact of the circular grooved pattern
evenly distributes chewing force, which prevents
the screw from loosening and the abutment from swaying.

▶When the abutment screw is fastened,
elastic deformation occurs around the grooves of the
SYLBUTMENT, creating a force which moves the abutment and
fixture together.
Even when the force is removed, the sealing effect can still be
maintained.

SYLBUTMENT
SYLBUTMENT
SYLBUTMENT
SYLBUTMENT

In a conventional abutment,
the gap between the fixture
and the abutment may increase gradually
due to repeated chewing forces.

The even surface contact of the circular
grooved pattern evenly distributes chewing force,
which helps prevent a gap
from Forming between the two surfaces

SYLBUTMENT
SYLBUTMENT

As shown in the above figure,
chewing forces are experienced asymmetrically due to the grooves of the
SYLBUTMENT acting as an elastic body.

This firmly maintains the sealed state of the abutment and distributes the
chewing forces evenly in the fixture.


1. Insert the abutment into the fixture.
2. Tighten the abutment screw 35N-cm until it fastens.
3. When the abutment screw expands, the exterior of the abutment connects to the interior of the fixture.
4. Apply chewing force.

01 If the length of the screw expands

5. Additional tensile force is applied to the abutment screw
(this causes the abutment screw to expand)
6. The abutment screw cannot resist the tensile force, and its shape permanently changes
7. The contact between the abutment and fixture is loosened
8. Eventually, the contact will break ,and the fixture and abutment will separate

02 If the screw twists involuntarily

5. To reduce the friction of the abutment screw, the screw will automatically loosen itself
6. Eventually, the contact will break , and the fixture and abutment will separate<

03 If the width of the abutment and fixture, which have been tightened by the abutment screw, is reduced.

5. When the interior of the fixture comes into contact with the abutment exterior, their shapes will be damaged
6. The width of the abutment and fixture , which have been tightened by the abutment screw, will reduce
7. Regardless of whether the abutment screw twists or expands, loosening will occur

 